IEEE Standard IEEE 802.3 10Base-T Ethernet    
IEEE 802.3u 100Base-TX Fast Ethernet    
IEEE 802.3ab 1000Base-T Gigabit Ethernet  
IEEE 802.3z 1000Base-X Gigabit Ethernet  
IEEE 802.3x Flow Control and Back Pressure  
IEEE 802.3af PoE (Power over Ethernet)  
IEEE 802.3at PoE+ (Power over Ethernetenhancements)  
Data Processing  Store and Forward    
Flow Control  IEEE 802.3x flow control, back pressure flow control  
Provides Broadcast
Storm Protection 
Present, Enable / Disable set by DIP SW  
Jumbo Frame  10K Bytes    
MAC Address Table  8K    
Packet Buffer Size  1Mbits    
PoE standard  IEEE 802.3at/af    
PoE RJ-45 pin
Assignment
RJ-45 port # 1~# 4 support IEEE 802.3at/af End-
Span, Alternative A mode
   
Positive (V+): RJ-45 pin 1, 2.    
Negative (V-): RJ-45 pin 3, 6.    
Data (1, 2, 3, 6, 4, 5, 7, 8 )    
Network Connector 4 x RJ-45 (IGS-402S-4PH24,
6 x RJ-45 (IGS-600-4PH24)
10/100/1000Base-T auto negotiation speed, Auto
MDI/MDI-X function, Full/Half duplex
   
2x 100/1000Base-X SFP (IGS-402S-4PH24)
2x1000Base-X Fiber connector: SC Muti Mode
   
Network Cable UTP/STP above Cat. 5e cable    
EIA/TIA-568 100-ohm (100m)    
Fiber Cable (Multi-mode): 50/125um, 62.5/125um
Fiber Cable (Single-mode): 9/125um
   
Protocols  CSMA/CD    
LED  Per unit: Power 1 (Green), Power 2 (Green), Fault (Amber)  
LED Per RJ-45 port : Link/Active (Green), Speed 10 (OFF ),
100 (Green), 1000 (Yellow)
   
Fiber Per port: Link/Active (Green)    
Per Port PoE LED
• Active : ON
• Inactive : OFF
• Fault : Flash
(Fault: Over Load, Short Circuit, Port failed at Startup)
   
DIP SW DIP 1 ON : Disable power failure alarm
OFF : Enable power failure alarm
 
DIP 2 ON : Disables broadcast storm
protection
OFF : Enable broadcast storm protection
 
DIP 3 ON : Fiber 2 for 100Base-FX SFP
OFF : Fiber 2 for Gigabit SFP
(Only for IGS-402S-4PH24)
 
DIP 4 ON : Fiber 1 for 100Base-FX SFP
OFF : Fiber 1 for Gigabit SFP
(Only for IGS-402S-4PH24)
 
Reserve Polarity
Protection 
Present    
Overload Current
Protection 
Present    
Power Supply Redundant Dual DC 24/48V (20~57VDC) Input
power (Removable Terminal Block)
Built-in very high efficiency booster(94~97%) to rise
up 55 VDC for PoE output
Regulate PoE output voltage (55VDC) to stabilize
PoE device, and guarantee delivery PoE power
distance to 100meter (Figure 2)
   
Power Consumption Input
Voltage
IGS-402S-
4PH24
IGS-600-
4PH24
24VDC 143.3W 142.9W
48VDC 138.2W 139.6W
PoE Power Output Maximum PoE Output power budget 120W (30W/Per Port)    
Alarm Relay Contact  Relay outputs with current carrying capacity of 1A @24VDC    
Removable Terminal Block Provides 2 Redundant power, Alarm relay contact, 6 Pin    
Operating
Temperature
-10 ~ 60°C (IGS-402S-4PH24,
IGS-600-4PH24)
   
-40 ~ 75°C (IGS-402S-4PHE24, IGS-600-4PHE24)  
Operating Humidity  5% to 95% (Non-condensing)    
Storage Temperature  -40 ~ 85°C    
Housing  Rugged metal, IP30 Protection and fanless  
Dimensions  106 x 62.5 x 134.8mm (D X W X H)    
Weight  0.84kg (IGS-402S-4PH24)
0.84kg (IGS-600-4PH24)
   
Installation Mounting  DIN Rail mounting or wall mounting    
MTBF  736,988 Hours @25°C (IGS-402S-4PH24)
649,579 Hours @25°C (IGS-600-4PH24)
(MIL-HDBK-217)
   
Warranty  5 years    
Certification
EMC CE    
EMI (Electromagnetic Interference) FCC Part 15 Subpart B Class A,CE EN55022 Class A  
Railway  Traffic EN50121-4    
Immunity for Heavy Industrial Environment EN61000-6-2    
Emission for Heavy Industrial Environment EN61000-6-4    
EMS
(Electromagnetic
Susceptibility)
Protection Level
EN61000-4-2 (ESD) Level 3, Criteria B    
EN61000-4-3 (RS) Level 3, Criteria A    
EN61000-4-4 (Burst) Level 3, Criteria A  
EN61000-4-5 (Surge) Level 3, Criteria B  
EN61000-4-6 (CS) Level 3, Criteria A    
EN61000-4-8 (PFMF, Magnetic Field) Field Strength:  
300A/m, Criteria A    
Safety  UL60950-1    
Shock  IEC 60068-2-27    
Freefall  IEC 60068-2-32    
Vibration  IEC 60068-2-6