Parameter Specification
COPPER TESTING  
Certification testing TIA 568-C.2 CAT 5e, 6, 6A, ISO/IEC 11801, EN 50173 Class D, E, EA, Patch-cord CAT 5e, 6, 6A testing
Max cable length for dual-ended Autotest 500 m
Insertion cycles Channel: 10,000 typical, Permanent link: 5,000 typical
TEST PARAMETERS As specified in TIA 1152, IEC 61935-1
Wiremap   
Loop Resistance  0 to 40 Ω, ±0.1 Ω  
Length  0 to 500 m, ±0.5 m (dual-ended testing)
Propagation Delay and Delay Skew  0 to 5000 ns, ±1 ns
Attenuation  0 to 70 dB, ±0.1 dB
Pair-to-Pair and Power-Sum NEXT  0 to 85 dB, ±0.2 dB
Pair-to-Pair and Power-Sum ACRF  0 to 85 dB, ±0.2 dB
Return Loss  0 to 40 dB, ±0.2 dB
ACRN, PSACRN  0 to 85 dB, ±0.5 dB
Advanced diagnostics Time-domain fault Locator for RL and NEXT
Measurement accuracy Exceeds TIA 1152 Level IIIe, IEC 61935 Level IIIe
Measurement frequency range 1-500 MHz
FIBER TESTING - SM  
Wavelengths 1,310 nm-1,550 nm
Connector type SC, LC (optional adapter needed)
Test standard TIA 568 C.3, IEC 14763-3
TEST PARAMETERS  
Loss 0 to 31 dB, ±0.2 dB
Length -5 dBm to -9 dBm
Output power  -5 dBm to -9 dBm
Receiver sensitivity -40 dBm
FIBER TESTING - MM/MMEF  
Wavelengths 850 nm-1,300 nm
Connector type SC/FC-SC
Test standard TIA 568 C.3, IEC 14763-3
TEST PARAMETERS  
Loss 0 to 24 dB, ±0.2 dB
Length 0 to 2,000 m, ±1.5 m
Dynamic range 24 dB/12 dB
Output power  -4 dBm to -10 dBm / -16 dBm to -20 dBm
Receiver sensitivity -34 dBm / -40 dBm
Encircled-Flux (EF) compliance IEC 61280-4-1 (MMEF)
VFL wavelength 650 µm (MMEF)
Power 0 dBm (MMEF)
GENERAL SPECIFICATIONS  
Interfaces Probe Interface, RJ-45 Ethernet, USB host and  device, talk set, power jack
Display 6" industrial LCD, touch sensitive area on both units
Enclosure Ruggedized plastic with rubber over-mold,  withstands 1.5 m drop test on hard surface
Remote unit abilities View test results, save tests, start autotest
Power supply AC 100-240 V to 12 V, 3A power adapter
Input over-voltage protection Protected against Telco voltages
Battery Removable and rechargeable Li-Ion
Battery capacity >8 hours continuous operation
Internal storage capacity >6,000 copper test results with full plot information for CAT 6A
External storage USB Flash Drive
Dimensions 223 X 124 X 70 mm
Weight 1 kg
Supported languages TW, CS, EN, FI, FR, DE, IT, JA, KO, PL, PT, RU, ES, SV, TR
Calibration period 1 year
ENVIRONMENTAL  
Operating temperature 0°C to 40°C
Storage temperature -20°C to 60°C
Relative humidity 10% to 80%
MINIMUM SYSTEM REQUIREMENTS FOR REPORTING SOFTWARE
Microsoft Windows Vista/7/8/10, 32 or 64 bits
Intel Core 2 Duo, 2 GHz  
200 MB of free disk space  
1 GB RAM  
Microsoft.NET Framework 4.0